Ergoldsbacher Großfalzziegel 
Overview Colours Technical data Roof references Downloads

Size
ca. 26,0 x 43,0 cm
Covering length
ca. 33,5 - 35,1 cm
Medium Covering width
ca. 22,4 cm
Supply required per m² (pieces)
ab 12,5
Weight per piece
ca. 3,6 kg
Weight per m² (DIN 1055)
ca. 0,55 kN/m²
Real weight
ca. 46 kg/m²
Pieces per pallet
224
Weight per pallet
ca. 830 kg
Bundle capacity (tiles)
4
Hail resistance class
4

Increased demands due to
Use
of the attic level, especially for residential purposes (residential use equals two increased demands)
Construction
  • Special roof shapes
    (e.g. butterfly roof)
  • Long spar lengths (longer than for normal single-family dwellings)
  • Heavily structured roof shapes (e.g. due to valleys, gables, etc.)
Climate situation
  • Exposed locations
  • Extreme locations
  • Areas with a lot of snow
  • Special weather situations
  • Areas with a lot of wind

1)
The additional measures listed in the table are minimum measures under consideration of Table 1 in the pamphlet on sub-roofs, sub-coverings and under-bracings. Sub-covering panels are to be assigned according to the classification in the pamphlet on sub-roofs, sub-coverings and under-bracings.
2)
Increased demands make up categories according to chapter 1.1.3. Further increased demands can arise out of the weighting within a category according to 1.1.3. For example, climate situations can result in several increased demands.
3)
Only permitted if proof is brought regarding functionality and safety of the products used, including accessories (sealing tapes, sticky tapes, sealing compounds, pre-assembled seam securing, etc.), as carried out in a severe rain test. Otherwise, the next class up is to be selected.

Assignment of additional measures 1)
According to the Central Association of German Roofers’ pamphlet on sub-roofs, sub-coverings and under-bracings, and the basic regulations of the Roofers’ Guild, regular roof pitch 25°, minimum roof pitch 10°, according to the state of technology.
for the Ergoldsbacher Großfalzziegel

Roof pitch

No further increased demands 2)

One further increased demand 2)

Two further increased demand 2)

Three further increased demand 2)

>=25°Klasse 6
3.3. under-bracing (USB-A)
Klasse 6
3.3. under-bracing (USB-A)
Klasse 5
2.4 overlapped / tongue in groove sub-covering (UDB-A, USB-A)
Klasse 4
2.2. welded or glued sub-covering
2.3. coated under-bracing made of strips of bitumen
3.2. seam-secured sub-covering (UDB-A, USB-A)
from <25°
to >=21°
Klasse 4
2.2. welded or glued sub-covering
2.3. coated under-bracing made of strips of bitumen
3.2. seam-secured sub-covering (UDB-A, USB-A)
Klasse 4
2.2. welded or glued sub-covering
2.3. coated under-bracing made of strips of bitumen
3.2. seam-secured sub-covering (UDB-A, USB-A)
Klasse 3
2.1. seam and perforation secured sub-covering
3.1. seam and perforation secured sub-covering (UDB-A, USB-A)
Klasse 3
2.1. seam and perforation secured sub-covering
3.1. seam and perforation secured sub-covering (UDB-A, USB-A)
from <21°
to >=17°
Klasse 3
2.1. seam and perforation secured sub-covering
3.1. seam and perforation secured sub-covering (UDB-A, USB-A)
Klasse 3
2.1. seam and perforation secured sub-covering
3.1. seam and perforation secured sub-covering (UDB-A, USB-A)
Klasse 3
2.1. seam and perforation secured sub-covering
3.1. seam and perforation secured sub-covering (UDB-A, USB-A)
Klasse 3 3)
2.1. seam and perforation secured sub-covering
3.1. seam and perforation secured sub-covering (UDB-A, USB-A)
from <17°
to >=13°
Klasse 2
1.2. rainproof sub-roof
Klasse 2
1.2. rainproof sub-roof
Klasse 1
1.1. waterproof sub-roof
Klasse 1
1.1. waterproof sub-roof
from <13°
to >=10°
Klasse 1
1.1. waterproof sub-roof
Klasse 1
1.1. waterproof sub-roof
Klasse 1
1.1. waterproof sub-roof
Klasse 1
1.1. waterproof sub-roof

Dominik Brunner Stiftung