High grade ceramic new building chimney SV single-storey Exhaust conduit for overpressure operation
Wichtigste Größen
SV 8 |
28 x 28 cm |
SV 10 |
34 x 34 cm
|
SV 12
|
34 x 34 cm |
SVI 8
|
28 x 40 cm |
SVI 10
|
34 x 46 cm |
SVI 12
|
34 x 46 cm |
SV 1808
|
38 x 62 cm |
SV 1810
|
38 x 62 cm |
SV 1812
|
38 x 62 cm |
SV 2008
|
40 x 69 cm |
SV 2010
|
40 x 69 cm |
SV 2012
|
40 x 69 cm |
SVI 1808
|
38 x 62 cm |
SVI 1810
|
38 x 62 cm |
SVI 1812
|
38 x 62 cm |
SVI 2008 |
38 x 62 cm |
SVI 2010
|
38 x 62 cm |
SVI 2012
|
38 x 62 cm |
I steht für zusätzlichen
Installationsschacht
(einzügig 8 x 24 cm,
zweizügig 6,5 x 20 cm).
Weitere Größen
siehe Preisliste
S.10 - 11, Sonder-
größen auf Anfrage
Application
Gas/oil condensing boilers
Chimney systems
Twin-shelled exhaust conduit, high-grade ceramic pipes, direct and counter current operation, for wet operation
Licence number
Z-7.2-3135 and Z-7.1-1512, CE identification for the high-grade ceramic pipes A1N1/A2P1/B2N1/D3P1, Heat Conduction Group IV (TR 00)
System components
High-grade ceramic pipe, prefabricated elements of up to 7.5 m, elastomer seals
Technical data
Moisture resistant for oil and gas condensing boiler technology, ambient air-independent or dependent, overpressure operation, low pressure also possible
Areas of application
Exhaust temperatures of 30 - 200° C, oil or gas
Recommended cross sections
For gas condensing boilers up to 25 kW 80 mm; calculate if over 25 kW! For oil condensing boilers up to 25 kW 80-120 mm depending on make